Combo Walking Floor (WFD)
Dual Pressure- 3000 PSI Walking Floor,
2000 PSI For Dump
Includes Air Shifter on Directional Control Valve
3 Line Systems Only
Air Pressure Must Be 80 PSI Minimum To Operate The High/Low Pressure Relief Air Cylinder
24 GPM @ 1200 RPM
30.5 GPM @ 1500 RPM
49 GPM @ 1800 RPM
The PTO Is Required To Operate At 130% Of The Engine Speed. In Most Applications The Engine RPM Is 1000 to 1200 RPM When Equipped W/ A our PTO, This Will Be A "C" Or "E" Ratio

Design Attributes
2 Levels of Performance to Suit Your Needs

-Standard Pump Features
-Heavy duty roller bearings
-Pressure balanced thrust plates
-High pressure shaft seals
-Aluminum detent cover
-Factory set relief pressure
-2 or 3 line configuration
-Extended mounting studs
-Doweled construction for higher pressure
-Manual inspection of spool shaft and visual inspection of pump
-Batch tested to assure proper flow, pressure, relief valve operation and overall efficiency

Premium “T” Pump Features
Heavy duty roller bearings
Pressure balanced thrust plates
-High pressure shaft seals
-Aluminum detent cover
-Factory set relief pressure
-2 or 3 line configuration
-Extended mounting studs
-Doweled construction for higher pressure
-Manual inspection of spool shaft and visual inspection of pump
-Test is conducted at 1000 RPMS
-Oil temperature is maintained at 100 degrees Fahrenheit
-Relief valve at full flow to not exceed 2300 PSI

In Order to Pass The Quality Test, The Pump Must Perform to The Following Specifications:
-Minimum flow of 25 GPM at 1500 PSI
-Relief valve maximum pressure differential (crack to full flow) to not exceed 250 PSI
-Minimum overall volumetric efficiency at 92% or more
-A copy of the computer generated test results is included with each pump
Weight: 95
Combo Walking Floor (WFD)
Dual Pressure- 3000 PSI Walking Floor,
2000 PSI For Dump
Includes Air Shifter on Directional Control Valve
3 Line Systems Only
Air Pressure Must Be 80 PSI Minimum To Operate The High/Low Pressure Relief Air Cylinder
24 GPM @ 1200 RPM
30.5 GPM @ 1500 RPM
49 GPM @ 1800 RPM
The PTO Is Required To Operate At 130% Of The Engine Speed.
Cross References
MakePart Number
Replacement NumberDG20-Z-L-AS-25/32
Industry NumberWFD-2.0WAS, MPN102650, BC102-20LAS-WFD, PMRDG20ZLAS2532, PMR-DG20-Z-L-AS-25/3, S S-18732, DG20-Z-L-AS-25/32C8T, MPGS-18732, ATX18732, DG20-Z-L-AS-25/32-RC, ATP18732, 18732SS, VIPDG20-Z-L-AS-25/32, DG20-Z-L-AS-25/32HTP, GTS18732, PSDG20-Z-L-AS-25/32, TF DG20-Z-L-AS-25/3
Customer NumberRF73650932
PermcoDG20-Z-L-AS-25/32, DG20-Z-L-AS-25-32

Heavy Duty Truck Parts

MHC stocks a large inventory of heavy-duty, all makes and models truck parts, from small pieces to major components, including rebuilt parts and exchange units. If a part isn't stocked at an MHC location, we leverage our network and all major OEM and component manufacturers' regional distribution centers to deliver hard-to-find parts to you quickly.

MHC employees at warehouse

Smooth sailing always with Murphy Hoffman and great being able to buy online beyond my local branch. Fast shipping and I always know I'm getting a quality product.

— Ti L.